Measuring Sound Power Levels of Air Terminal Devices and Valves in Reverberation Rooms - ISO 5135

2023-06-26 23:25:03 By : admin
ISO 5135 - Acoustics - Determination of Sound Power Levels of Noise from Air Terminal Devices, High/Low Velocity/Pressure Assemblies, Dampers and Valves by Measurement in a Reverberation Room

Noise pollution is a major concern of our modern society, and it affects human health, comfort, and productivity. The noise generated by air terminal devices, high/low velocity/pressure assemblies, dampers, and valves in HVAC systems is a significant contributor to the indoor noise level. The ISO 5135 standard provides a method for measuring the sound power levels of such devices in a reverberation room.
ISO 5135 - Acoustics - Determination of Sound Power Levels of Noise from Air Terminal Devices, High/Low Velocity/Pressure Assemblies, Dampers and Valves by Measurement in a Reverberation Room First Edition | Engineering360


A reverberation room is a specially designed chamber where sound waves reflect off the walls and ceiling repeatedly, creating a diffuse sound field with a consistent sound pressure level throughout the room. This makes it an ideal location for measuring the sound power level of a noise source.

The ISO 5135 standard outlines the procedures and requirements for conducting such measurements. To begin the test, the device under test (DUT) is installed inside the reverberation room and connected to a sound level meter and a power analyzer. The DUT is then excited by a controlled sound source with a known sound power level.

Measurements are taken at multiple positions throughout the room, and the resulting data is analyzed to determine the sound power level of the DUT. This value represents the total acoustic power radiated by the DUT, which can be used to calculate the noise level it generates.

The ISO 5135 standard provides a precise and repeatable method for measuring the sound power levels of HVAC components, allowing manufacturers to design quieter and more efficient systems. The standard also benefits building owners and occupants by ensuring that the HVAC system is not a source of excessive noise, which can contribute to stress, annoyance, and reduced productivity.

There are many devices available on the market that can measure noise levels, but not all of them are suitable for measuring sound power levels. To comply with ISO 5135, a device must be capable of measuring the sound pressure level at multiple positions in the reverberation room and calculating the sound power level of the DUT. Therefore, it is important to choose a device that is specifically designed for this application.

In conclusion, ISO 5135 is a crucial standard for the HVAC industry, as it provides a method for measuring the sound power levels of air terminal devices, high/low velocity/pressure assemblies, dampers, and valves in a reverberation room. By complying with this standard, manufacturers can design quieter and more efficient systems, and building owners and occupants can enjoy a peaceful and productive indoor environment. It is essential to use a device designed specifically for measuring sound power levels to ensure accurate and reliable results.